Brief Introduction
MPO cassette are generally used to install in the 1U or 3U panel (rack), MPO-LC harness patch cords, LC adapters, MPO adapters are connected and installed in the cassette, all of them have mounted and tested, can be used directly. MPO cassette has 12 core and 24 core. This is a very popular product of MPO cabling in data center..
Features
1.High quality ferrule and accurate alignment by PIN and PIN hole.
2.MPO comes in many types and design blueprint can be provided quickly.
3.Standard Loss(IL≤0.7dB) and Low Loss(IL≤0.35dB) insertion loss are available.
4.The Connector end-face can meet the interference index.
5.Connector compliant with IEC 61754-7(Type MPO connector family).
Applications
1.High density cabling system.
2.Cabling in communication base station and distribution case.
3.Jumper connection. 40G and 100G system, QSFP module.
4.Optical fiber communication system,CATV,LANs and WANs
Specifications
Connector A | MPO Female | Connector B | LC |
Fiber Mode | MM50/125um OM3 | Test Wavelength | 850/1300nm |
Polish Type | PC to PC | Minimum Bend Radius | 10mm |
Insertion Loss | ≤0.70dB(0.40dB Typ.) | Return Loss | ≥25dB |
Attenuation at 850nm | ≤2.3dB/KM | Attenuation at 1300nm | ≤0.6dB/KM |
Cable Jacket | LSZH | Cable Jacket O.D | 3.0mm |
Installation Tensile Load | 120N | Long-Term Tensile Load | 50N |
Operating Temperature | -20℃ to +70℃ | Storage Temperature | -40℃ to +85℃ |
Detailed Images
![]() | About MPO Connector The MPO connectors used are in accordance with the standard IEC 61754-7 and IEC 61754-10, using the international well-known brand connectors. Sufficient SGS report and reliability test report. |
About MPO Insertion Loss All MPO fiber patch cord have been 100% double-wavelength tested, ensuring insertion loss of less than 0.70db, typical value is 0.30db, and return loss must be more than 25dB. Also, there is a low loss(IL≤0.35db)connector for customers to choose. | ![]() |
How to choose fiber? What is the difference about Several type multimode fiber?
OM4 and OM3 fiber are Gigabit fiber, various performance indexes is better than OM1 and OM2.
Fiber Type | Core/Cladding (um) | Light Source | Bandwidth @850nm OFL (MHZ·KM) | Bandwidth @850nm EMB (MHZ·KM) | 10Gpbs Ethernet 10G BASE SR/LR | 40Gpbs Ethernet 40G | 100Gpbs Ethernet 100G BASE SR10/IR4 |
OM1 | 62.5/125 | LED | 200 | Nonsupport | 33M(SR) | Nonsupport | Nonsupport |
OM2 | 50/125 | LED | 500 | Nonsupport | 82M(SR) | Nonsupport | Nonsupport |
OM3/150 | 50/125 | VSCEL or LED | 700 | 950 | 150M(SR) | 50M(SR4) | 50M(SR10) |
OM3/300 | 50/125 | VSCEL or LED | 1500 | 2000 | 300M(SR) | 100M(SR4) | 100M(SR10) |
OM4 | 50/125 | VSCEL or LED | 3500 | 4700 | 500M(SR) | 150M(SR4) | 150M(SR10) |
OFL= Over Filled Launch; EMB=Effective Modal Bandwidth
Before produce, it is necessary to confirm whether MPO connector is male or female.
Female, without guide PINS Male, with guide PINS
How to realize high density MPO cabling system?
We produce high quality MPO cable which is widely used in high density cabling systems. In addition to MPO Cable, we also provide MPO Cassette and 19′ rack in line with customer needs, for complete the MPO cabling solution.
![]() | Our Quality Control We use highly reliable testing equipment. Each product must pass 100% test to ensure that all the products are reliable, good consistency and meet the international standards. Here, you can see our equipments and test methods. Learn More... |