8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable

Quick Details
Cores number: 8 Male/Female: MPO Female
Fiber Type: Multimode OM4 Cable Type: 3.0mm breakout cable
Jacket Material: LSZH MPO/IL<0.70dB; LC/IL<0.30dB

Model Number: #21506SL Category:

Brief Introduction

8fibers single-mode MPO-LC fan-out patch-cord usually used for 40G QSFP+ module to 4x10G SFP module, generally use 12 fibers MPO connector on both sides of the four channels for Receive and Transmit signal, that is four channels for Receive signal and other four channels for transmit signal. MPO connector and duplex LC connector are respectively connected with the 40G QSFP+ module and 10G SFP module. Also, 12fibers, 24fibers is available. For the LC Uniboot connector, there are two fibers in a loose tube(2.0mm) . A 2.0mm loose tube instead of 2.0mm duplex loose tube. There are two LC connectors have only one Boot. This page product of LC connector is duplex connector, one connectoer one BOOT.

Features

1.High quality ferrule and accurate alignment by PIN and PIN hole.
2.MPO comes in many types and design blueprint can be provided quickly.
3.Standard Loss(IL≤0.7dB) and Low Loss(IL≤0.35dB) insertion loss are available.
4.2fibers in one 2.0mm loose tube.
5.MPO Connector compliant with IEC 61754-7 and LC duplex connector.

Applications

1.High density cabling system.
2.Cabling in communication base station and distribution case.
3.Jumper connection. Fiber optics system for 40G to 4x10G.
4.Optical fiber communication system,CATV,LANs and WANs.

Product Video

Specifications

Connector A MPO Female Connector B LC duplex
Fiber Mode Multimode 50/125um OM4 Test Wavelength 850/1300nm
Polish Type PC to UPC Minimum Bend Radius 32mm
MPO Insertion Loss ≤0.70dB(0.40dB Typ.) MPO Return Loss ≥25dB
LC  Insertion Loss ≤0.30dB(0.15dB Typ.) LC Return Loss ≥30dB
Attenuation at 850nm ≤2.3dB/KM Attenuation at 1300nm ≤0.60dB/KM
Cable Jacket LSZH Cable Jacket O.D 3.0mm breakout 2.0mm
Installation Tensile Load 120N Long-Term Tensile Load 50N
Operating Temperature -20℃ to +70℃ Storage Temperature -40℃ to +85℃

Detailed Images

8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable


8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber CableAbout MPO Connector

The MPO connectors used are in accordance with the standard IEC 61754-7 and IEC 61754-10, using the international well-known brand connectors. Sufficient SGS report and reliability test report.

About MPO Insertion Loss

All MPO fiber patch cord have been 100% double-wavelength tested, ensuring insertion loss of less than 0.70db, typical value is 0.30db, and return loss must be more than 25dB. Also, there is a low loss(IL≤0.35db)connector for customers to choose.
8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable

8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber CableAbout Cable Material

LSZH is one of the most commonly used optic cable in our factory, the higher fire protection grade cable is available, such as OFNP. All cable materials are meet with IEC/CE/UL/Rohs2.0 standards.

Cable Structure Diagram

12core bare fiber, kevlar from DuPont company, LSZH material, Aqua color jacket, OD.=3.0mm.
8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable

How to choose fiber? What is the difference about Several type multimode fiber?

  • The ISO/IEC 11801 standard specifies categories OM1, OM2, OM3, OM4 and OM5.
  • The TIA/EIA also recognizes OM1 through OM5. The TIA/EIA ratified OM5 in June 2017 (TIA-492AAAE).
  • The IEEE ratified OM4 (802.ba) in June 2010 and updated the standard in 2012 to incorporate higher speeds. The forthcoming IEEE 802.3-2018 standard will include OM5.
Fiber Type Core/Cladding Light Source Bandwidth @850nm OFL Bandwidth @850nm EMB Bandwidth @953nm OFL Bandwidth @953nm EMB Bandwidth @1300nm OFL Bandwidth @1300nm EMB 10Gpbs Ethernet 10G BASE SR/LR 40Gpbs Ethernet 40G 100Gpbs Ethernet 100G BASE SR10/IR4
OM1 62.5/125u LED 200MHz·KM Nonsupport N/A 33M(SR) Nonsupport Nonsupport
OM2 50/125um LED 500MHz·KM Nonsupport N/A 82M(SR) Nonsupport Nonsupport
OM3/150 50/125um VSCEL/LED 700MHz·KM 950MHz·KM N/A 150M(SR) 50M(SR4) 50M(SR10)
OM3/300 50/125um VSCEL/LED 1500MHz·KM 2000MHz·KM N/A 500MHz·KM N/A 300M(SR) 100M(SR4) 100M(SR10)
OM4 50/125um VSCEL/LED 3500MHz·KM 4700MHz·KM N/A 500MHz·KM N/A 500M(SR) 150M(SR4) 150M(SR10)
OM5 50/125um VSCEL/LED 3500MHz·KM 4700MHz·KM 500MHz·KM Not required 1850MHz·KM 2470MHz·KM

OFL= Over Filled Launch;  EMB=Effective Modal Bandwidth


For the LC connector, there are several types for customers to choose.

The MPO-LC breakout cable acts as a bridge for 40G to 10G connections. The 40G QSFP+ optical transceiver is directly connected to the MPO connector, and the 10G SFP optical transceiver is connected to the duplex LC connector.

 8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable

 8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable

Before produce, it is necessary to confirm whether MPO connector is male or female.

8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable

Female, without guide PINS                                                      Male, with guide PINS


How to confirm the MPO connector what you need is male or female?

Type1: Connection between MPO and MPO
Connection between two MPO connectors, which must be one MPO connector is Female and another one must be Male.
8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable

8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber CableType2: Connection between MPO and optical module
You know, All optical modules are self-contained with Guide PIN, it means male MPO connector inside, so when connection between MPO cable and optical module, the MPO connector on cable must be the female connector.

How to realize high density MPO cabling system?

We produce high quality MPO cable which is widely used in high density cabling systems. In addition to MPO Cable, we also provide MPO Cassette and 19′ rack in line with customer needs, for complete the MPO cabling solution.

 8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable

How does the MPO cable patchcord connect to the switch in 40G system?

The MPO cable patch-cord is directly connected to the QSFP-40G-SR4 optic module. Type-B and Female MPO connector is required. The optic module is connected to the switches directly. Show as the figure.

 8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable

Packing

NOTE: The following images are for reference only in their packaging style. If the MPO cable is long and big, which will be packing with plastic wrap.

8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable


8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber CableOur Quality Control

We use highly reliable testing equipment. Each product must pass 100% test to ensure that all the products are reliable, good consistency and meet the international standards. Here, you can see our equipments and test methods.

Learn More...

 

8C MPO-LC MULTIMODE DATASHEET

This DATASHEET is 8-Core MPO connector to LC connector pre-terminated breakout cable, multimode 50/125um fiber 3.0mm trunk fan-out cable LSZH cable

8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable 8 Fibers OM4 Multimode LSZH Purple Jacket MPO Female to 4xLC Duplex Breakout Optical Fiber Cable

This drawing is for reference only. If you need more information and need to modify the drawing, please Email us:support@vchung.com

Q1. What is your terms of packing?

Answer: A: Generally, we pack our goods in ziplock bag and brown cartons. If you have special requirements, please let us know and we will try our best to cooperate with you.

Q2. What is your terms of payment?

Answer: A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.

Q3. What is your terms of delivery?

Answer: A: EXW, FAS, FOB, FCA, CFR, CPT, CIF, CIP.

Q4. How about your delivery time?

Answer: A: Generally, it will take 2 to 10 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.

Q5. Can you produce according to the samples?

Answer: A: Yes, we can produce by your samples or technical drawings.

Q6. What is your sample policy?

Answer: A: We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and the courier cost.

Q7. Do you test all your goods before delivery?

Answer: A: Yes, we have 100% test before delivery.

Q8: How do you make our business long-term and good relationship?

Answer: A:1. We keep good quality and competitive price to ensure our customers benefit ; 2. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.

Get A Free Product Quote

Simply fill in your requirement below to get your free, no obligation quotation today!
Your inquiry will be replied within 12 hours, and we respect your privacy.

Contact Us

Email Us: Just email us and we will review it carefully and get you a response in 12 hours. 

Orders

sales@vchung.com

Inquire about our product information and service details before ordering.

Technical Support

tech@vchung.com

Resolve technical uncertainties and we will give a full analysis and resolve it.

Call Us

Tel & Fax: +86-755-81481899

This is an English language line and there will be a salesperson to communicate with you.

Skype Chat

Skype ID: gamvinhuang

Add gamvinhuang as a friend, then feel free to chat with us on skype.

Scroll to Top

Product Inquiry