Brief Introduction
Super Tap cable assemblies provide the most cost-effective method of deploying optical fiber in outside plant distribution networks at speeds significantly fast than traditional field installations. The assemblies guarantee an easy, one-step connection system with the combined push-pull insertion and nut-style mechanical latch. Super Tap cable assembly provides quick installation solutions and has good performance on mating with Super Tap adapter. Cable can be armored or non-armored. Super Tap connector utilizes optical fiber cables upon which network access points are pre-installed at customer-specified locations along the length of the cable.
Features
- Cost effective solution for in house termination.
- Low insertion loss and added loss.
- Height of attenuation.
- IP67 water, dust proof and corrosion resistant.
- The material in the jumpel cable are all-weather and UV-resistant.
- Mechanical performance: IEC 61754-4 standard.
- RoHS and REACH materials compliant.
Applications
- Multi-purpose Outdoor.
- For connection between distribution box and RRH.
- Deployment in Remote Radio Head cell tower applications.
Specifications
Connector Types
Type | Reference | Note | |
SC | IEC 61754-4 | Single mode Simplex | APC: Green connectors UPC: Blue connectors |
Multimode Simplex | UPC: Grey Connectors |
Dimensional Diagrams
Mini IP SC Outer Cable Assemblies
Patchcord versions
Jumper tolerance requirement | |
Overall length (L) (M) | length of tolerance(CM) |
0<L≤20 | +10/-0 |
20<L≤40 | +15/-0 |
L>40 | +0.5%L/-0 |
Trunk 5.0mm Cable Structure
Cable Parameter
Cable Core | Out Sheath Diameter(MM) | Weight(KG) | Minimum Allowable Tensile Strength (N) | Minimum Allowable Crush Load(N/100mm) | Minimum Bending Radius (MM) | Storage temperature(℃) | |||
short term | long term | short term | long term | short term | long term | ||||
1 | 5.0±0.2 | 26.5 | 800 | 400 | 2000 | 1000 | 20D | 10D | -20 ~~ +60 |
4.0×7.0mm Flat Dr0p Cable Structure
Flat Dr0p Cable Parameter
Cable Core | Out sheath Diameter(MM) | Weight(KG) | Minimum Allowable Tensile Strength (N) | Minimum Allowable Crush Load(N/100mm) | Minimum Bending Radius(MM) | Storage temperature(℃) | |||
short term | long term | short term | long term | short term | long term | ||||
1 | (4.0±0.2)x(7.0±0.2) | 42 | 1350 | 400 | 2200 | 1000 | 20D | 10D | -20 ~~ +60 |
Optical Characteristics
Item | Parameter | Reference | |||
Single mode | Multimode | ||||
Standard | Elite | Standard | Elite | ||
Insertion loss | Typical≤0.30dB Max≤0.75dB | Typical≤0.15dB Max≤0.35dB | Typical≤0.50dB Max≤0.25dB | Typical≤0.10dB Max≤0.35dB | IEC 61300-3-34 |
Return loss | ≥ 50dB (PC) ≥ 60dB (APC) | ≥ 55dB (PC) ≥ 65dB (APC) | ≥30dB(PC) | ≥30dB(PC) | IEC 61300-3-6 |
End-Face Geometry
Item | UPC (Ref: IEC 61755-3-1) | APC (Ref: IEC 61755-3-2) |
Radius of curvature (mm) | 10 to 25 | 5 to 12 |
Fiber height (nm) | -100 to 100 | -100 to 100 |
Apex offset (μm) | 0 to 50 | 0 to 50 |
APC angle (°) | / | 8° ±0.2° |
Key error (°) | / | 0.2° max |
End-Face Quality (SM)
Zone | Range (μm) | Scratches | Defects | Reference |
A: Core | 0 to 25 | None | None | IEC 61300-3-35:2015 |
B: Cladding | 25 to 115 | None | None | |
C: Adhesive | 115 to 135 | None | None | |
D: Contact | 135 to 250 | None | None | |
E: Rest of ferrule | None | None |
End-Face Quality (MM)
Zone | Range (μm) | Scratches | Defects | Reference |
A: Core | 0 to 65 | None | None | IEC 61300-3-35:2015 |
B: Cladding | 65 to 115 | None | None | |
C: Adhesive | 115 to 135 | None | None | |
D: Contact | 135 to 250 | None | None | |
E: Rest of ferrule | None | None |
Mechanical Characteristics
Test | Conditions | Reference |
Endurance | 500 matings | IEC 61300-2-2 |
Vibration | Frequency: 10 to 55Hz, Amplitude: 0.75mm | IEC 61300-2-1 |
Cable retention | 100N (main cable); 50N (connector part) | IEC 61300-2-4 |
Strength of coupling mechanism | 80N for 2 to 3mm cable | IEC 61300-2-6 |
Cable torsion | 15N for 2 to 3mm cable | IEC 61300-2-5 |
Fall | 10 drops, 1m drop height | IEC 61300-2-12 |
Static lateral load | 1N for 1h (main cable); 0.2N for 5min (ranch part) | IEC 61300-2-42 |
Cold | -25°C, 96h duration | IEC 61300-2-17 |
Dry heat | +70°C, 96h duration | IEC 61300-2-18 |
Change of temperature | -25°C to +70°C, 12 cycles | IEC 61300-2-22 |
Humidity | +40°C at 93%, 96h duration | IEC 61300-2-19 |
Packing
NOTE: The following images are for reference only in their packaging style. If the MPO cable is long and big, which will be packing with plastic wrap.
![]() |
![]() | Our Quality Control We use highly reliable testing equipment. Each product must pass 100% test to ensure that all the products are reliable, good consistency and meet the international standards. Here, you can see our equipments and test methods. Learn More... |